Hp Dl180 G6 Expansion Slots

Slots
Print|Rate this content

Front panel components

Front Panel Components / 4 3.5” HDD Model

Description
Front panel USB 2.0 port 0/1
Optical disc drive
System health LED
Front UID LED/switch
NIC 1 activity LED
NIC 2 activity LED
Hard Drive activity LED
Power LED/switch
Thumbscrews for rack mounting
Drive online/error LED
Drive activity LED
Hard disk drive (HDD) bays

Front Panel Components / 8 3.5” HDD Model

Description
Front panel USB 2.0 port 0/1
Optical disc drive
Front UID LED/switch
System health LED
NIC 1 activity LED
NIC 2 activity LED
Hard Drive activity LED
Power LED/switch
Thumbscrews for rack mounting
Drive activity LED
Drive online/error LED
Hard disk drive (HDD) bays

Front Panel Components / 12 3.5” HDD Model

Description
Front panel USB 2.0 port 0/1
System health LED
Front UID LED/switch
NIC 1 activity LED
NIC 2 activity LED
Hard Drive activity LED
Power LED/switch
Thumbscrews for rack mounting
Drive online/error LED
Drive activity LED
Hard disk drive (HDD) bays

Rear panel components

Rear Panel Components for Standard PCI Cage

Description
Power supply 2 cable socket
Serial port
T-10/T-15 wrench
GbE LAN port for NIC 2
Dedicated management port (optional)
Low-profile PCI expansion card slot cover
Full-height/full-length PCI expansion card slot covers
Rear UID LED/switch
GbE LAN port for NIC 1
Rear panel USB 2.0 port 2/3
VGA port
Power supply 1 cable socket

Rear Panel Components for HDD PCI Cage

Description
Power supply 2 cable socket
Serial port
T-10/T-15 wrench
GbE LAN port for NIC 2
Dedicated management port (optional)
Low-profile PCI expansion card slot cover
Hard disk drive (HDD) bay
Rear UID LED/switch
GbE LAN port for NIC 1
Rear panel USB 2.0 port 2/3
VGA port
Power supply 1 cable socket

Rear Panel Components for DVD-ROM PCI Cage

Description
Power supply 2 cable socket
Serial port
T-10/T-15 wrench
GbE LAN port for NIC 2
Dedicated management port (optional)
Optical disk drive (ODD) bay
Full-height/full-length PCI expansion card slot covers
Rear panel USB 2.0 port 2/3
GbE LAN port for NIC 1
Rear UID LED/switch
VGA port
Power supply 1 cable socket

System board components

Designator
1
PCIe slot
J11
3
PCIe slot
J21
5
DIMM slot 1D for processor 2
CPU2
7
DIMM slot 6C for processor 1
J60
9
DIMM slot 1D for processor 1
J51
11
Processor 1
J63
13
Fan connector 2
J64
15
Fan connector 3/4 (Fan 4 is unused)
J69
17
Backplane I2C connector
J68, J67
19
Hard drive backplane SGPIO connector
J79
21
3 V CMOS battery (CR2032)
J76
23
LCD connector (optional)
J53
25
Front panel header
J29
27
System maintenance jumper
SATA
29
PCIe slot

Link to the related do cument

Click here to view the LED Indicators page for the HP ProLiant DL180 G6 Server series .

Link to the list of available documents

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence. PCI Expansion Card Slot 5. Front USB Ports (2) 5. PCI Expansion Card Slot 6. Non-Hot Plug Non Redundant fans (4 fans) 6. UID LED Button 7. Air Baffle 7. View and Download HP ProLiant DL180 Generation 6 (G6) quickspecs online. High capacity storage optimized 2-way server. ProLiant DL180 Generation 6 (G6) Server pdf manual download. Also for: Proliant dl180 generation 6, Proliant dl180 g6. HPE ProLiant DL180 Gen6 (G6) Server. The HPE ProLiant DL180 Gen6 server is a dual-processor platform powered by Intel's 5520 chipset. The system's twelve memory slots, generous internal storage, and basic remote management features offer the perfect solution for growing SMB environments.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!
  1. Was the information on this page helpful?
Please wait while we process your request.

Dl180 G6 Quickspecs

Print|Rate this content

Introduction

This document is provided to assist in removing and replacing the PCI expansion board/PCI cages for the HP ProLiant DL180 G6 Server series.

Minimum skill level

The End-User must possess extensive product-specific knowledge and technical skill on how to service the system, and be familiar with the operating system.

Parts required

The replacement part number will vary depending on the PCI expansion board/PCI cages that is being replaced. If a part is listed as 'Yes' under 'Requires Return' then the defective part needs to be returned to HP. Click here for more information on returning parts to HP.

Part Number
Riser board 3 PCI-E
Yes
454357-001 (Original)
NOTE: For customers in countries/regions with RoHS legislation* (e.g. EU,China, etc.) restricting the use of hazardous substances in electricalequipment.The use of the Original Spare part is regulated by RoHS legislation. If yourunit contains a part that is labelled with the Modified Spare number, theModified Spare must be ordered as the replacement part.If your unit contains a part that is labelled with the Original Spare number,please order the Original Spare as the replacement part. In this case eitherthe Original Spare or the Modified Spare may be shipped which will notaffect performance or functionality of the unit.

Summary of instructions

To view a video demonstrating the procedure for removing the PCI expansion board/PCI cages, click on the link below. Or use the product video listing on the HP Services Media Library, (Click here to go to HP Service Media Library), then select PCI expansion board/PCI cages from the menu on the upper left hand side of the screen.

Click here to view the PCI expansion board/PCI cages removal video (right-click on the link to open in a new window/tab).

PCI expansion board/PCI cages removal

  1. Review the safety considerations before performing the steps listed below by clicking on the following link:

    Click here to view the precautions.

    CAUTION: Failure to comply with the precautions could result in damage to your product or loss of data.
  2. Remove the top cover. Click here for instructions on how to remove the top cover .

  3. Remove the air baffle. Click here for instructions on how to remove the air baffle .

  4. Remove the PCI cage. Click here for instructions on how to remove the PCI cage .

  5. Remove the screw near the slot cover on the PCI cage.

  6. Remove the slot cover from the PCI cage.

  7. Slide the expansion board into the slot, aligning the board with its matching connector. Firmly press the board to seat it properly on the slot.

  8. Tighten the screw that secures the expansion board to the PCI cage.

PCI expansion board/PCI cages replacement

  1. To reinstall the PCI cage:

    1. Install the PCI expansion board into the PCI cage.

      1. Align the PCI expansion board with the open expansion slot.

      2. Press the PCI expansion board into the expansion slot on the riser card.

      3. Tighten the screw that secures the expansion board to the PCI cage.

    2. Align the PCI cage assembly to the system board expansion slot, and then press it down to ensure full connection to the system board.

    3. Tighten the thumbscrews to secure the PCI cage assembly to the system board and secure the screw on the rear panel of the chassis.

    4. Connect the necessary cable(s) to the system board.

  2. To install the hard disk drive PCI cage:

    1. Loosen the thumbscrew and screws that secure the hard disk drive PCI cage to the system board.

    2. Lift the hard disk drive PCI cage assembly away from the system board.

    3. Align the four backplane holes to the corresponding standoffs on the hard disk drive PCI cage, and then push the card down.

    4. Tighten the screw that secures the backplane to the hard disk drive PCI cage.

    5. Align the hard disk drive PCI cage assembly to the system board expansion slot, and then press it down to ensure full connection to the system board.

    6. Tighten the thumbscrew to secure the hard disk drive PCI cage assembly to the system board and secure the screws on the side and the rear panel of the chassis.

    7. Pull the rear hard drive blank out of the hard disk drive PCI cage assembly.

    8. Push the hard dive assembly into the drive bay until it stops.

    9. Press the hard disk drive carrier latch inward until it clicks.

  3. To install the DVD-ROM PCI cage:

    1. Loosen the thumbscrews that secure the DVD PCI cage to the system board and remove thescrew on the rear panel of the chassis.

    2. Lift the DVD PCI cage away from the system board.

    3. Push the DVD ROM into the DVD PCI cage.

    4. Tighten the screw that secures the DVD-ROM to the DVD PCI cage.

    5. Align the DVD PCI cage assembly to the system board expansion slot, and then press it down to ensure full connection to the system board.

    6. Tighten the thumbscrews that secure the DVD PCI cage assembly to the system board and secure the screw on the rear panel of the chassis.

  4. Replace the PCI cage. Click here for instructions on how to replace the PCI cage .

  5. Replace the air baffle. Click here for instructions on how to replace the air baffle .

  6. Replace the top cover. Click here for instructions on how to replace the top cover .

Parts return

If your part requires return then click on the appropriate link below:

Click here for the defective parts return procedure for US.

Click here for the defective parts return procedure for Europe.

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Hp Dl180 G6 Power Supply

Provide feedback

Please rate the information on this page to help us improve our content. Thank you!

Hp Dl180 G6 Drivers

  1. Was the information on this page helpful?

Hp Dl180 G6 Bios Update

Please wait while we process your request.